Z6950-XL Faucets
Adjustable modes and features selection:
To adjust features from default configuration, you must remove the battery tray. Once battery tray is removed you will see the switches.
Purge Features:
The purge switches can be configured for 4 modes of operation: Disabled (standard configuration), 12 hour, 24 hours, or 48 hours. Purge water flow duration is 2 minutes. Note: Purge activation occurs every switch selected time (0,12, 24, or 48 hours) after last activation.
Flow Time:
There are 6 optional time configurations: 30 seconds (standard), 5s, 10s, 15s, 60s, & “Less Time-out”. The “Less Time-out” option actually ceases water flow (turns off) after 20 minutes to limit chance of water damage in the event a sink drain becomes blocked .
Sensing Mode (DEFAULT):
During this mode the valve will shut off after hands are removed. If hands are not removed the time out delay will turn off the faucet (ex: standard configuration is 30 seconds)) (See Sensing & Metering Mode flow chart above page)
Metering Mode:
When hands are detected by the sensor, water will run for ‘ X’ seconds (standard configuration is 30 seconds) before turning off. (See Sensing & Metering Mode flow chart on following page)
Sensor Sensitivity: (Default setting: Low):
There are 4 sensitivity options, which can be selected to achieve the optimal detection performance related to the sink material, shape, & finish. The faucet sensor sensitivity is configured during pack-out but the mode can be changed upon installation to
optimize the performance within the sink. Sensor sensitivity and sensor detection Modes A & B may be tried for various lighting conditions, sink materials and shape.
Switch 7 controls the sensitivity
-On (default) is normal sensitivity for most sinks providing max range.
-Off set the sensor to a lower sensitivity level for sinks that cause false activation. The detection range maybe less for all hands. Switch 8 controls sensor mode
-On (default) enables the mode that filters the effects of flowing in the bottom of problematic sinks. Detection maybe less for some hands.
-off disable the filter mode, so detection is expanded deeper into the sink for max detection range for all hands. Some sinks may only be able to operate in this mode.
NOTE: After a configuration switch change has been made. Disconnect sensor cable from electronics box, wait 30 seconds, then reconnect sensor cable and wait 30 additional seconds to allow the sensor to tune-in the sink characteristics. Calibration includes characterizing the sink with water running into the bowl. This could be 5 to 60 seconds depending on configuration.
Water is not getting cold | ||
---|---|---|
Problem | Cause | Corrective Action |
Compressor is warm or hot & fan will not shut off |
|
|
|
|
|
Compressor is room temperature. Fan runs continuously |
|
|
Compressor is room temperature & fan will not run. |
|
|
Compressor or inside of water cooler is hot. Fan is not running |
|
|
Compressor is making a loud knocking or grinding noise |
|
|
Water runs out of bubbler continuously | ||
Problem | Cause | Corrective Action |
Water cooler is an EZ, HTV, or electric eye series water cooler and water runs even when the power cord is not plugged in |
|
|
Water cooler is an EZ, HTV series water cooler and water stops immediately every time when you unplug the power cord from the outlet |
|
|
Water cooler is an EHF, WC, HAC, or EMABF series water cooler |
|
|
Water cooler or fountain model other than previous listed |
|
|
Water won't flow intermittently | ||
Problem | Cause | Corrective Action |
Water cooler was manufactured prior to 2001 & water is very cold |
|
|
Water quality problem (taste or odor) | ||
Problem | Cause | Corrective Action |
Water has a taste or odor problem |
|
|
Water stream is too low | ||
Problem | Cause | Corrective Action |
Stream is too low after initial installation of the product |
|
|
Water stream is too high | ||
Problem | Cause | Corrective Action |
Water stream is too high |
|
|
No Water Flow | ||
Problem | Cause | Corrective Action |
Water cooler is an EZ, HTV, or electric eye operated model |
|
|
No water flow on all other water coolers/fountains |
|
|