Sloan Royal 186-0.125-ES-S Sensor Flushometer


calcActive())">
h3. Specifications
Quiet, Exposed, Diaphragm Type, Chrome Plated Urinal Flushometer for either left or right-hand supply with the following features:
* High Chloramine Resistant PERMEX® Synthetic Rubber Diaphragm with Linear Filtered Bypass and Vortex Cleansing Action™
* Vacuum Breaker with Flush Connection
* Sweat Solder Adapter with Cover Tube and Cast Wall Flange
* Low Consumption flush accuracy
* ¾” I.P.S. Screwdriver Bak-Chek® Angle Stop with Vandal Resistant Stop Cap
* Spud Coupling and Spud Flange for ¾” Top Spud
* No External Volume Adjustment to Ensure Water Conservation
* OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2.
* Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX® rubber compound for Chloramine resistance
h3. Control Circut
* Solid State
* 8 Second Arming Delay
* 24 VAC Input
* 24 VAC Output
h3. Solenoid Operator
* 24 VAC, 50/60 Hz
h3. Sensor Range
* Nominal 12” - 32” (305 mm - 813 mm) Self-adaptive Window: ± 10” (254 mm)
h3. Automatic Operation
Sloan OPTIMA® equipped Flushometers provide the ultimate in sanitary protection and automatic operation. There are no handles to trip or buttons to push. The Flushometer operates by means of an infrared sensor that adapts to its surrounding. Once the user enters the sensor’s effective range and then steps away, the Flushometer Solenoid initiates the flushing cycle to flush the fixture.
h3. Hygenic
User makes no physical contact with the Flushometer surface except to initiate the Override Button when required. Helps control the spread of infectious diseases.
h3. Economical
Automatic operation provides water usage savings over other flushing devices. Reduces maintenance and operation costs.
h3. Practical
Solid state electronic circuitry assures years of dependable, trouble-free operation. The operational components of the Flushometer are identical to a handle activated Sloan® Flushometer, proven by over 100 years of experience.
In stock
- SKU
- 169242
$537.58
Description / Sloan Royal 186-0.125-ES-S Sensor Flushometer
h3. Specifications
Quiet, Exposed, Diaphragm Type, Chrome Plated Urinal Flushometer for either left or right-hand supply with the following features:
* High Chloramine Resistant PERMEX® Synthetic Rubber Diaphragm with Linear Filtered Bypass and Vortex Cleansing Action™
* Vacuum Breaker with Flush Connection
* Sweat Solder Adapter with Cover Tube and Cast Wall Flange
* Low Consumption flush accuracy
* ¾” I.P.S. Screwdriver Bak-Chek® Angle Stop with Vandal Resistant Stop Cap
* Spud Coupling and Spud Flange for ¾” Top Spud
* No External Volume Adjustment to Ensure Water Conservation
* OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037 and ANSI/ASME 112.19.2.
* Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX® rubber compound for Chloramine resistance
h3. Control Circut
* Solid State
* 8 Second Arming Delay
* 24 VAC Input
* 24 VAC Output
h3. Solenoid Operator
* 24 VAC, 50/60 Hz
h3. Sensor Range
* Nominal 12” - 32” (305 mm - 813 mm) Self-adaptive Window: ± 10” (254 mm)
h3. Automatic Operation
Sloan OPTIMA® equipped Flushometers provide the ultimate in sanitary protection and automatic operation. There are no handles to trip or buttons to push. The Flushometer operates by means of an infrared sensor that adapts to its surrounding. Once the user enters the sensor’s effective range and then steps away, the Flushometer Solenoid initiates the flushing cycle to flush the fixture.
h3. Hygenic
User makes no physical contact with the Flushometer surface except to initiate the Override Button when required. Helps control the spread of infectious diseases.
h3. Economical
Automatic operation provides water usage savings over other flushing devices. Reduces maintenance and operation costs.
h3. Practical
Solid state electronic circuitry assures years of dependable, trouble-free operation. The operational components of the Flushometer are identical to a handle activated Sloan® Flushometer, proven by over 100 years of experience.
More Information
Manufacturer | Sloan |
---|---|
Model # | ROYAL 186-0.125-ES-S |
Manufacturer Part # | 3772695 |
Toilet/Urinal | Urinal |
Gallons Per Flush (GPF) | 0.125 GPF |
Vacuum Breaker Length | 9" |
Spud Size | 3/4" |
Write Your Own Review