Sloan G2 Flushometer Battery Replacement
When Required, Replace Batteries With Four (4) Alkaline AA-Size Batteries.
- Loosen the two (2) Screws on top of unit.
- Remove the complete Cover Assembly.
- Lift the Sensor Module from its Plate. Unplug the Electrical Connector from Battery Compartment Cover.
- Loosen the Retaining Screw on Battery Compartment Cover and remove Battery Compartment Cover.
- Install four (4) Alkaline AA-Size Batteries.
- Install Battery Compartment Cover and secure with Retaining Screw. Make certain that Battery Compartment Cover is fully compressed against Gasket to provide a seal; Do Not overtighten.
- Plug the Electrical Connector into the Battery Compartment Cover.
- Reinstall the Sensor Module onto the Plate.
- Reinstall the complete Cover Assembly onto the Plate.
- Tighten the two (2) Screws on top of the unit.
Note: Water does not have to be turned off to replace Batteries.